All Products · A-Series

A-Series · Hurricane aluminum

A-150 Impact Storefront

Hurricane Impact

A 150 mm solid aluminum storefront: a framed, impact-rated glazing wall for ground-floor commercial elevations in hurricane and high-wind zones.

Frame
Solid aluminum · 150 mm
Opening
Fixed
Glass package
Laminated impact insulating glass
Whole-window U-value
0.5 Calculated
Certified: third-party tested (NFRC, CSA) Calculated: LBNL THERM / WINDOW Project-specific: by size and glass

The deepest A-Series section, built to span a storefront bay and carry large laminated impact units. Solid aluminum for maximum strength in hurricane and high-wind zones, powder-coated or anodized to match the rest of the envelope.

Technical specifications
System depth150 mm
Frame material6063-T6 aluminum (solid)
GlassLaminated impact insulating glass
ImpactLarge-missile, hurricane / high-wind  Project-specific
ApprovalsFlorida & coastal code basis  Project-specific
Whole-window U-value≈0.5 Btu/ft²·h·°F  Calculated
FinishPowder-coated or anodized

Certified values are published as NFRC and CSA testing completes. Calculated values come from LBNL THERM and WINDOW models of the specific assembly. Project-specific values depend on size and glass package.

What is a fixed window?

A fixed window does not open. With no sash movement or operating hardware, it delivers the slimmest sightlines and the largest possible area of glass, and it can be made in almost any shape, including arches, circles, triangles, and trapezoids. Fixed units are used wherever daylight and a view matter but ventilation is handled elsewhere.

See all window & door types ›

Glass & glazing options
Laminated impact insulating glass. Low-E and solar-control coatings, warm-edge spacers, argon or krypton fill, laminated and acoustic packages to suit the project.
Hardware
Corrosion-resistant coastal hardware with multi-point locking. Handle finishes in nine anodized and powder-coated options — see Finishes.
Sizes & configurations
Single and coupled multi-lite arrangements. Maximum sizes are governed by the weight of the glass package and, for the A-Series, the design wind load; see drawings for limits.
Drawings & details
Head, jamb, and sill sections, anchoring and interface details, and DXF profiles available on request while the drawing library is finalized.
Installation
Rough-opening tolerances, substrate requirements, and air-barrier interface guidance follow the A-Series installation manual. See Air Barrier Interface and Installation.