A 70 mm inward-opening fiberglass swing door — a deeper, higher-performing entry and balcony door than the GR60, with multi-point locking and a low-threshold option.

Frame
Pultruded fiberglass · 70 mm
Opening
Swing
Glass package
Hybrid vacuum ZERO 05 or ZERO 04, double or triple · up to 40 mm
Whole-window U-value
0.115R-8.7 CalculatedU in Btu/h·ft²·°F with ZERO 04 glass · 0.119 / R-8.4 with ZERO 05
Certified: third-party tested (NFRC, CSA) Calculated: LBNL THERM / WINDOW Project-specific: by size and glass

An inward-swinging fiberglass door on a deeper 70 mm frame for better thermal performance. Multi-point locking pulls the leaf to a full-perimeter seal, and a low, accessible threshold keeps the transition flush.

Technical specifications
Frame depth70 mm
Frame materialPultruded fiberglass, powder-coated
Glazing pocketUp to 40 mm
OpeningHinged, inward swing
LockingMulti-point
ThresholdStandard or low / accessible
Whole-window U-value, ZERO 040.115 Btu/h·ft²·°F (0.65 W/m²K), R-8.7, at NFRC size 960 × 2090 mm  Calculated
Whole-window U-value, ZERO 050.119 Btu/h·ft²·°F (0.67 W/m²K), R-8.4  Calculated
Whole-window U-value, ZERO 24 double glazed0.235 Btu/h·ft²·°F (1.34 W/m²K), R-4.2, within the Massachusetts energy code  Calculated
Center-of-glass U-valueZERO 04: 0.044 to 0.047 Btu/h·ft²·°F (R-21 to R-23) · ZERO 05: 0.054 (R-18.5)  Calculated
SHGC, center of glassKØLD 0.49 / 0.35 · MILD 0.35 / 0.27 · HEIT 0.26 / 0.20 (ZERO 05 / ZERO 04)  Calculated
Visible light, center of glassKØLD 76% / 64% · MILD 67% / 53% · HEIT 61% / 45% (ZERO 05 / ZERO 04)  Calculated

Certified values are published as NFRC and CSA testing completes. Calculated values come from LBNL THERM and WINDOW models of the specific assembly. Project-specific values depend on size and glass package.

What is a swing door?

A swing door is hinged on one side and opens like a standard door, inward or outward. Multi-point locking draws the leaf tight to a continuous perimeter seal, and a low, accessible threshold keeps the transition flush. Swing doors suit entries, balconies, and terraces.

See all window & door types ›

Thermal section (THERM heat map)
GR70 Swing Door head temperature map
Room · 70°FOutside · 0°F
0°F10°F20°F30°F40°F50°F60°F70°F
-15°C-10°C-5°C0°C5°C10°C15°C20°C

GR70 Swing Door · Head. Whole door 0.115 Btu/h·ft²·°F (R-8.7) with ZERO 04, 0.119 (R-8.4) with ZERO 05, at 960 × 2090 mm. Calculated

Modeled in LBNL THERM 8.1 at NFRC winter conditions, 0°F outside and 70°F inside. The red band on the room side shows the frame and glass staying close to room temperature; the lines are isotherms every 3°C (5.4°F).

Glass & glazing options

Standard glazing is the hybrid vacuum unit in one of six ZERO packages: three climates, each at two levels. ZERO 05 Daylight admits the most light and solar heat; ZERO 04 Ultimate has the lowest U-factor. For code-level projects, the double-glazed ZERO 24 packages are also available.

PackageCenter-of-glass U / R · SHGC · visible light
KØLD 05 · cold0.054 / R-18.5 · 0.49 · 76%
KØLD 04 · cold0.047 / R-21.1 · 0.35 · 64%
MILD 05 · mixed0.054 / R-18.6 · 0.35 · 67%
MILD 04 · mixed0.044 / R-22.6 · 0.27 · 53%
HEIT 05 · hot0.054 / R-18.6 · 0.26 · 61%
HEIT 04 · hot0.044 / R-23.0 · 0.20 · 45%
ZERO 24 KØLD · double glazed0.244 / R-4.1 · 0.57 · 83%
ZERO 24 MILD · double glazed0.241 / R-4.1 · 0.40 · 73%
ZERO 24 HEIT · double glazed0.242 / R-4.1 · 0.30 · 68%

Quanex Super Spacer® Premium silicone-foam warm-edge spacer, argon-filled outer cavity.

Triple glazing, laminated and acoustic build-ups are also available to suit the project. Compare the ZERO packages ›

Hardware
German tilt-turn hardware with concealed hinges and multi-point locking. Handle finishes in nine anodized and powder-coated options — see Finishes.
Sizes & configurations
Single and coupled multi-lite arrangements. Maximum sizes are governed by the weight of the glass package and, for the A-Series, the design wind load; see drawings for limits.
Drawings & details
Head, jamb, and sill sections, anchoring and interface details, and DXF profiles available on request while the drawing library is finalized.
Installation
Rough-opening tolerances, substrate requirements, and air-barrier interface guidance follow the F-Series installation manual. See Air Barrier Interface and Installation.
Downloads & resources